Three exposures, three different questions

Salt spray

ISO 9227 uses an artificial salt-spray atmosphere to assess corrosion. It does not directly reproduce showering, swimming or daily sweating.

Water exposure

Define the water type, contact time and acceptance criteria. Fresh water and chlorinated pool water should not be treated as identical exposures.

Artificial perspiration

A defined perspiration solution is used to evaluate surface behaviour. Its conditions differ from neutral salt spray; resistance to sweat needs relevant evidence.

Our actual 48-hour necklace record

The published record concerns one gold-colour metal necklace submitted by Yiwu Jinming Jewelry Co., Ltd. Its rating applies only to that sample under the recorded laboratory conditions, not the whole catalog or every production batch.

ReportRTS260909M4459SL
Report date11 September 2026
SampleOne gold-colour metal necklace · material no. 001
Exposure48 hours · continuous neutral salt spray · ISO 9227:2022
Appearance / protection rating10/10

The rating is not a general waterproof, sweatproof or lifetime guarantee. We do not convert it into a blanket PASS claim.

Read the sample-specific salt spray records
Open the complete 48-hour English report (PDF)

What this record does not establish

No bathing, swimming or artificial-perspiration results are provided in the cited Jinming record. This salt spray report alone cannot verify those use claims or establish a number of years of normal wear.

ISO 9227 explicitly cautions against using salt spray methods to predict long-term corrosion resistance.

Intertek's jewelry High-Performance programme lists separate procedures for sweatproof, waterproof and tarnish-resistant claims. These are examples of its programme, not certifications awarded to Jinming.

Before using a waterproof or sweatproof claim

  • Identify the SKU, base material, finish and sample or batch.
  • Specify the intended exposure: daily splashes, showering, pool water or perspiration.
  • Agree duration and acceptable changes in colour, corrosion, surface or coating.
  • Keep the test report and before/after observations tied to the submitted sample.

Ask the laboratory to agree a product-specific method and rating rules; do not assume one test protocol fits every design. For coated items, the coating and components also belong in the brief.